User Tools

Site Tools


Navigation


aixcon PowerSystems GmbH

Steinfurt 26
D-52222 Stolberg (map)

Tel.: +49 (0) 2402 12210
FAX: +49 (0) 2402 122122


Impressum

Mikrowellengeneratoren

Since 15 years aixcon develops and manufactures microwave generators for high-end applications. The aixcon microwave generators Y-2000 and Y-3000 raise the bar of highly dynamic, precise and reproducible microwave technology. A compact design and distinguished technical features enable the deployment of many new applications. A rapid setup and integration into complex systems is facilitated through standardized interfaces.

The high voltage supply and the magnetron heater run with switch mode power supplies and produce only low losses. The water cooling makes the system well suited for deployment in clean room environment. The intelligent control unit of the water cooling also increases the life-time of the magnetron significantly.

Even without measuring the MW-power directly, a high precision is achieved. This is achieved with the help of a new control system which takes the degradation of the magnetron into account.

The pulse mode supports frequencies of up to 20kHz and a pulse power with a factor of 1.5 of the nominal power.

  • precise control in constant RF-mode and pulse-mode
  • long-term stability of the calibration
  • high dynamic range, RF-pulse frequency of up to 20 kHz
  • high energy efficiency
  • analog and many field bus interfaces
  • compact and light design

Applications

Wafer treatment:
aixcon microwave generators are deployed worldwide in the manufacturing process steps like etching and cleaning of semi-conductors and micro chips.

Glass coating:
aixcon mircowave generators are deployed in the manufacturing process of effect glass with electrostatic or UV triggered darkening, mirroring and infrared filter. Further applications are the manufacturing of cold mirrors for halogen lights.

Automotive Technology:
Highly stressed components in internal combustion engines, like vaults, vault stems, injectors etc. are treated with aixcon's microwave generators.

Y-2XX Y-3XX Y-6XX
Generator
Input Voltage 3 phase 400 V AC, 50 Hz/480 V, 60 Hz
Ripple very low ripple < 1 %
Modulated Pulse Mode 0 – 1 kHz (with pulse shaping)
Fast Pulse Mode (FPM) (at output stage) Optional: 0 – 20 kHz (with pulse edge conditioning)
Efficiency 92% 92% 93%
Operating Conditions
Cooling Air or Water cooled Water cooled
Housing 3 U 19” Aluminum Housing 4 U 19” Aluminum Housing
Interlock excess temperature, mains failure
Magnetron Head
Filament Supply Voltage/Control Signal Provided by Generator
MW Output Power 100 W – 2000 W cw / upto 3 kW pulse 100 W – 3000 W cw / upto 4.5 kW pulse 100 W – 6000 W cw / upto 9 kW pulse
MW Frequency 2.45 GHz ± 20 MHz
Cooling Air or Water cooled Water cooled
Interlock excess temperature of magnetron or coolant, supply voltage
Software Interface
Interface Analog 0-24 V, Profinet, CAN-Bus (optional) , Profbibus (optional), Ethercat (optional) Further interfaces on request
Configuration Interface Ethernet with integrated DHCP server, Ethernet over USB (optional)
Configuration Software Web based configuration interface over Ethernet (OS independent and no software installation necessary)
Event log .csv/.xls/.xlsx files, other formats on request



All connectors are pluggable on the back panel.















Print this!Mail this!